EasyManua.ls Logo

Gecko in.xe - Troubleshooting: Keypad Not Working

Gecko in.xe
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
in.xe TechBook
45
•  Replace transformer 
fuse.
•  If problem persists, 
replace spa pack.
•  Verify if keypad is correctly connected to the spa pack.
If spa is not heating,
follow this troubleshooting flow chart:
Flow chart
Spa not heating / flow chart & step-by-step
yes
Are there
any error
messages
on the
keypad
display?
Ensure
 temp 
set point is
higher
 than
actual
 water 
temp.
no
Refer to specific  
error mes
sage
section.
Has Heater
indicator
appeared
on keypad
display?
yes
no
Do you get
a 240 V
reading
between the
two heater
terminals
on the board?
yes
no
Replace 
spa pack.
Are heater
screws properly
connected to
the heater?
yes
no
Replace 
heater.
Take water
temp and 
compare with
temp
 value 
displayed
on
 k
eypad
.
Is differ
ence
greater than
2°F?
yes
no
System 
works
 fine.
yes
no
Replace 
heater.
Tighten 
screws 
properly
Is ther
e
still a
problem?
Problem 
solved.
Replace 
heater.
Accessory fuse