in.xe TechBook
Step-by-step field replacement procedure
in.xe
Step-by-step field replacement
procedure
As part of our technical support services, this section
provides step-by-step methods to facilitate the 
replacement of in.xe spa packs in the field.
Tools needed:
• Phillips & flat screwdrivers 
• Multimeter
• Open-ended adjustable wrench
• Scraper tool
• Pliers
• GFCI tester
All procedures described in this service manual 
must only be performed by qualified personnel, in 
accordance with the standards applicable in the country 
of installation.
Disconnect incoming 
power lines by loosening 
the screws on the terminals 
of the terminal block.
Carefully revise the spa 
plumbing schematics and 
identify the spa flow shut 
off valves. Make sure that
both flow shut off valves
which control water 
inlet before and after the 
heater are closed.
Unplug all HC (high
current) outputs. e.g.: 
pumps, blower or any 
other accessories. 
Warning!
When replacing an 
in.xe spa pack, make 
sure to turn power off
before proceeding.
With a Phillips screwdriver 
or a flat screwdriver 
loosen the 2 screws of
the spa pack door and 
open it.