80208G_MHW_650-1250-1350_01-2017_ENG
28
2.4.2. Power supply
2.4.3. Inputs
2.4.4. Outputs
Characteristics of outputs Out1, Out2, Out3, Out4 are defi-
ned when the controller is ordered.
6
5
6
5
5
3
Output Out 1 – 5 A relay
5 A relay 250 VAC / 30 VDC
NO
C
6
5
Output Out 1 – logic
Logic 24 V
(10 V to 20 mA)
+
-
L
+V
6
6
5
3
2
Output Out 1 – continuous
4...20 mA Continuous
Rout < 500 Ω
+
-
19
20
8
7
23
24
NO
C
Output Out 2 – 5 A relay
5 A relay 250 VAC / 30 VDC
2. INSTALLATION
6
5
4
3
2
1
Linear input (V,I)
linear input voltage
60 mV (Ri > 70 kΩ)
1 V (Ri > 15 kΩ)
+
-
Linear input in direct
current
0/4...20 mA, Ri = 50 Ω
Attention:
with this type of connection the
line resistance can introduce me-
asurement error, we recommend
that you use wires of adequate
screen.
The resistance of the three wires
must be equal, the line resistance
must be less than 20 ohm.
5
4
3
2
1
T
Input PT100/JPT100 - 3-wires connection
Attention:
with this type of connection the line
resistance can introduce measure-
ment error, we recommend that
you use wires of adequate.
5
4
3
2
1
T
Input PT100/JPT100 - 2-wires connection
Powe supply
Standard: 100...240VAC/DC ± 10%
50/60Hz, max 10VA
Optional: 20...27VAC/DC ± 10%
50/60Hz, max 10VA
12
11
10
22
23
24
~
~
PWR
(*)
(*) ground connection only to option
20...27VAC/DC