ADV200 • Functions description and parameters list 109
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.11 2446 Slip P gain perc FLOAT 1.0 0.0 100.0 ERWS V
Setting of the slip compensation proportional gain.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.12 2448 Slip I gain perc FLOAT 1.5 0.0 100.0 ERWS V
Setting of the slip compensation integral gain.
Vf limit
Torque lim Pos Inuse
PAR 2360
Torque lim Neg Inuse
PAR 2362
Torque curr lim Pos
PAR 2350
Torque curr lim Neg
PAR 2352
Torque curr lim sel
PAR 2354
Vfcurrent limItime
PAR 2362
Vfcurrent lim P time
PAR 2460
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.13 2460 Vfcurrent lim P gain Hz/A FLOAT CALCF 0.0 1000.0 ERWS V
Setting of the proportional gain limit in V/f mode. This is calculated automatically if the self-tuning procedure is
performed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.14 2462 Vfcurrent lim I time ms FLOAT CALCF 1.0 50.0 ERWS V
Setting of the proportional gain limit in V/f mode. This is calculated automatically if the self-tuning procedure is
performed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.15 2466 Instability comp en ENUM Disable 0 1 ERWZ V
This parameter enables/disables the current stabilization of an asynchronous motor controlled in V/F. It may
happen that in certain operational situations the motor could show unstable behavior (excessive oscillations of
the current) in conditions of zero load (low values of load) and at low speeds. if active, this function is able to
control these oscillations making the system stable.
0 Disable
1 Enable
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.16 2468 Instability comp K ohm FLOAT CALCF 0 200.0 ERWS V
This parameter denes the gain value of the instability compensator. The value is automatically calculated by the
drive when the motor data are inserted and the Take parameters command (PAR 2020) is executed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.17 2480 Vf min frequency Hz FLOAT 1.0 0.2 5.0 ERW V
Setting of the minimum frequency in the V/f control mode. This represents the minimum output frequency,
below which frequency regulations are ineffective. It is not possible to go below this value, regardless of the
reference that has been set.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals