110 ADV200 • Functions description and parameters list
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.18 2482 Vf min freq delay ms UINT16 800 0 5000 ERW V
Setting of the delay for the minimum frequency signal in the V/f control mode.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.19 2490 Dig Vf scale FLOAT 16/32 1.0 0.0 1.0 ERWZ V
Setting of a digital multiplier factor for the drive output voltage in the V/f mode.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.20 2492 Vf scale src LINK 16/32 3374 0 16384 ERW V
Selection of the origin (source) of the signal to be used to set a multiplier factor for the drive output voltage. The
associable functions are listed in the “L_VREF” selection list.