ADV200 • Functions description and parameters list 165
If set to 8 the datum is assigned engineering units on a 32-bit integer.
If set to 9, the datum is assigned a 16-bit integer engineering unit format not in real time (5-10ms)
If set to 10 the datum is assigned a 32-bit integer engineering unit format or oat format if the associated pa-
rameter is a oat-type parameter not in real time (5-10ms)
Note ! If the sys parameter is not assigned, none of the subsequent channels are transferred to the fieldbus, even if programmed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.4.3 4184 Dig Fieldbus S->M1 INT32 16 0 0 0 ERW FVS
23.4.7 4194 Dig Fieldbus S->M2 INT32 16 0 0 0 ERW FVS
23.4.11 4204 Dig Fieldbus S->M3 INT32 16 0 0 0 ERW FVS
23.4.15 4214 Dig Fieldbus S->M4 INT32 16 0 0 0 ERW FVS
23.4.19 4224 Dig Fieldbus S->M5 INT32 16 0 0 0 ERW FVS
23.4.23 4234 Dig Fieldbus S->M6 INT32 16 0 0 0 ERW FVS
23.4.27 4244 Dig Fieldbus S->M7 INT32 16 0 0 0 ERW FVS
23.4.31 4254 Dig Fieldbus S->M8 INT32 16 0 0 0 ERW FVS
23.4.35 4264 Dig Fieldbus S->M9 INT32 16 0 0 0 ERW FVS
23.4.39 4274 Dig Fieldbus S->M10 INT32 16 0 0 0 ERW FVS
23.4.43 4284 Dig Fieldbus S->M11 INT32 16 0 0 0 ERW FVS
23.4.47 4294 Dig Fieldbus S->M12 INT32 16 0 0 0 ERW FVS
23.4.51 4304 Dig Fieldbus S->M13 INT32 16 0 0 0 ERW FVS
23.4.55 4314 Dig Fieldbus S->M14 INT32 16 0 0 0 ERW FVS
23.4.59 4324 Dig Fieldbus S->M15 INT32 16 0 0 0 ERW FVS
23.4.63 4334 Dig Fieldbus S->M16 INT32 16 0 0 0 ERW FVS
If associated with the relative src, the value of this parameter is sent to the bus.
The user may modify the M->S and by S->M sys parameters. The consistency of the sys with the parameter
assigned to the channel is checked.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.4.4 4186 Fieldbus S->M1 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.8 4196 Fieldbus S->M2 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.12 4206 Fieldbus S->M3 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.16 4216 Fieldbus S->M4 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.20 4226 Fieldbus S->M5 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.24 4236 Fieldbus S->M6 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.28 4246 Fieldbus S->M7 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.32 4256 Fieldbus S->M8 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.36 4266 Fieldbus S->M9 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.40 4276 Fieldbus S->M10 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.44 4286 Fieldbus S->M11 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.48 4296 Fieldbus S->M12 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.52 4306 Fieldbus S->M13 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.56 4316 Fieldbus S->M14 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.60 4326 Fieldbus S->M15 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.64 4336 Fieldbus S->M16 mul FLOAT 1.0 1.0 1000.0 ERW FVS
The “Fieldbus S->Mx mul” parameters are multipliers that the drive applies to the datum before sending it to
the bus. It is therefore possible to increase the resolution of some values read in EU and EU_oat mode, also

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals