EasyManuals Logo

gefran ADV200 User Manual

gefran ADV200
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #171 background imageLoading...
Page #171 background image
ADV200 • Functions description and parameters list 171
These parameters are not used on the master drive.
On the slave drive these parameters show the value received from the previous drive. The “Inv” parameters en-
able the value received to be used with the opposite sign, without changing any of the data sent to subsequent
slaves.
These parameters are available in the src analog parameter selection lists.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.21 5850 FL Rev 1 mon INT32 32BIT 0 0 0 ER FVS
23.8.22 5852 FL Rev 2 mon INT32 32BIT 0 0 0 ER FVS
23.8.23 5854 FL Rev 3 mon INT32 32BIT 0 0 0 ER FVS
23.8.24 5856 FL Rev 4 mon INT32 32BIT 0 0 0 ER FVS
Display of data selected via parameters FL Rev X Slave sel corresponding (PAR 5822 ... 5828).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.25 5822 FL Rev 1 slave sel UINT16 0 0 31 ERWZ FVS
23.8.26 5824 FL Rev 2 slave sel UINT16 0 0 31 ERWZ FVS
23.8.27 5826 FL Rev 3 slave sel UINT16 0 0 31 ERWZ FVS
23.8.28 5828 FL Rev 4 slave sel UINT16 0 0 31 ERWZ FVS
Parameter signicant only for Master drive, indicates what data of which Slave drive to display in parameter
FL Rev X mon (you can choose to display word 1 or 2 of a Slave with address from 2 to 16). The code used
assigns the signicance of the rst word of the Slave at address 2 to value 0, value 1 for the rst word of the
Slave at address 3 …. 14 rst word of the Slave at address 16, 15 has no signicance, 16 second word of
Slave at address 2 … 30 second word of Slave at address 16.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.29 5720 Sync slave mon BIT 16 0 0 1 ER FVS
This parameter is not signicant on the master drive.
On the slave drives this parameter indicates the state of the function that enables Pwm signals to be synchro-
nised with the Pwm signals of the master and execution of control tasks to be synchronised with execution of
control tasks of the master.
0 Slave not synchronised
1 Slave synchronised
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.30 5722 FL fault code UINT32 0 0 0 ER FVS
This parameter is used to display the cause of the FastLink fault alarm.
See chapter C - FastLink Fault.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals