EasyManuals Logo

gefran ADV200 User Manual

gefran ADV200
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #190 background imageLoading...
Page #190 background image
190 ADV200 • Functions description and parameters list
This parameter is active only with control mode V/F
It indicates the state 1 when the motor speed is below the value set in parameter P940. It indicates the state 0
when the motor speed is greater than the value set in parameter P940.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
944 Speed is 0 BIT 16 0 0 1 ER
This parameter is active when the speed is below the threshold set in parameter 940 Speed 0 threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
946 Speed is 0 delay BIT 16 0 0 1 ER
This signal is active when the reference is below the threshold set in parameter 940 Speed 0 threshold. The
signal is activated after the delay set in parameter 942 Speed 0 delay.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
956 Speed thr 1_2 mon BIT 16 0 0 1 ER
To display the speed threshold status: if the motor speed is higher than the value set in parameter 950 Speed
threshold 1 or lower than the value set in parameter 952 Speed threshold 2 this parameter assumes the
value of 0.
If the motor speed is between the value of 950 Speed threshold 1 and that of 952 Speed threshold 2, this
parameter assumes the value of 1.
Use parameter 954 Speed threshold dly to set a delay time for the transition from 0 to 1 of parameter 956
Speed thr 1_2 mon; the transition from 1 to 0 is always immediate.
When 950 Speed threshold 1 is set to a value higher than 952 Speed threshold 2, if the motor speed is be-
tween the thresholds this parameter assumes the value of 1. If 950 Speed threshold 1 is set to a value lower
than 952 Speed threshold 2, the threshold status is not signicant
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
966 Set speed BIT 16 0 0 1 ER
This signal is active when the error between the speed reference and actual motor speed is greater than the
tolerance set in parameter 962 Set speed error.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
976 Speed thr 3 mon BIT 16 0 0 1 ER
The status of the block that detects exceeding of the speed 3 threshold is displayed.
0 Actual speed below threshold
1 Actual speed above threshold
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
986 Current thr mon BIT 16 0 0 1 ER
The status of the block that detects exceeding of the current threshold is displayed.
0 Actual output current below threshold
1 Actual output current above threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1030 Local/remote mon BIT 16 0 0 1 ER
This signal is active when the drive is in the Remote operating mode.
0 Local
1 Remote
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1060 Sequencer status UINT16 16 0 0 0 ER

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals