ADV200 • Functions description and parameters list 47
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.16 982 Current thr hyster perc UINT16 0 0 100 RW FVS
Setting of the tolerance band around the current threshold. A value of 100% corresponds to the value of the
drive heavy duty continuous current, displayed in parameter 488 Drive cont current, when parameter 566
Drive overload mode is set to Heavy duty, and no derating of the drive continuous current has been activated
due to any modication of Mains voltage, Switching frequency and Ambient temperature.
The drive heavy duty continuous current value to be used is the factory setting read in PAR 488 Drive cont
current.
The tolerance band is the same for both directions of rotation of the motor.