819XX_MAN_GRM-H_11-2022_ENG_pag. 80
•
Default parameters - Identification
Index Sub-index Name of the object
Access
Length
Data
type
Value (example) Description
U M S
0x0010 0x00 VendorName
RO RO RO 10 String
GEFRAN spa
0x0011 0x00 VendorText
RO RO RO 14 String
www.gefran.com
0x0012 0x00
ProductName RO RO RO
Max64
String
GRM-120-48-I-1-x-
x-x-x-x
Full product description
0x0013 0x00 ProductID
RO RO RO 12 String
GRM-xxxxxxxxx Model type
0x0014 0x00 ProductText
RO RO RO
Max30
String
Single-phase Power
controller
Functional description of
the product
0x0015 0x00 SerialNumber
RO RO RO 8 String 20400102
Product serial number
0x0016 0x00 HardwareRevision
RO RO RO
3
String 1.0
0x0017 0x00 FirmwareRevision
RO RO RO
3
String 1.0
Software version
0x0018 0x00 ApplicationSpecicTag
RO RW RW
Max32
String
*** (Default)
The user can specify the function
and location of the device in the
system in the tag
0x0019 0x00
FunctionTag RO RW RW
Max32
String
Vuoto (Default)
The user can specify the function
and location of the device in the
system in the tag
0x001A 0x00
LocationTag RO RW RW
Max32
String
Vuoto (Default)
The user can specify the function
and location of the device in the
system in the tag
U = User, M = Maintenance technician, S = Specialist
•
Default parameters - Diagnosis
Index Sub-index Name of the object
Access
Length Data type Value (example) Description
U M S
0x0020 0x00 ErrorCount
RO RO RO 2
UInt16
0
Incremental counter of
errors from power-on
0x0024 0x00 DeviceStatus
RO RO RO 1
UInt8
See the following
table (Device Status
Values)
Denes the status of the
device
0x0025
0x01
0x02
0x03
0x04
DetailedDeviceStatus
RO RO RO
Variable
(Array di 4
elementi, 3
bytes per
elemento)
See the following
Tables (Errors and
warnings in the
Detailed Device
Status and Error
Code)
Species the detailed
status of the Device:
Octet 1 = EventQualier
(see IO-Link standard)
Octet 2, 3 = EventCode
See tables below
0x0028 0x00 ProcessDataInput
RO RO RO
PD length PD
0
Read the last valid
Process Data from the
PDin channel
•
Values of the Device Status
Value Description
0x00 The device works correctly (no error / warning)
0x01 Maintenance required
0x02 Out of specication
0x03 Functional check
0x04 Failure