Ch.8129
——— Parameters lists ———
Value Access via
Keyp. RS485/Terminal Opt2-A
minmaxFactory BUS//PDC
Opt2-M
Drive ready 380U16 0 1--RQD R
Drive ready 1H
Drivenot ready 0 L
Quick stop 343U16 0 1Noquick stop (1) - R/W ID R/W
Quick stop 0 L
No Quick stop 1H
F
ast stop 316 U16 0 1Nofast stop (1) - R/W 14 R/W
Fast Stop 0 L
No Fast Stop 1H
Enabledrive314 U16 0 1 Disabled (0)
Ö
R/W 12 R/W
Enabled 1H
Disabled 0 L
Ramp ref 1 [FF] 44 I16
-2 x P45 +2 x P45
0
Ö
R/W IA, QA R/W
(Speed input var)
Start/Stop 315U16 0 1 Stop (0)
Ö
R/W 13 R/W
Start 1H
Stop 0 L
Actual spd(rpm) 122 I16 -8192 8192 -
Ö
RQAR
Motor cur rent [A] 231 Float 0 S -
Ö
RQA-
Mains voltage 333 U16 02400 V (1)
Ö
R/Z - -
230 V 0
400 V 1
460 V 2
Ambient temp[°C] 332 U16 0 140°C(1)
Ö
R/Z - -
50°C(122°F) 0
40°C(104°F) 1
Rated drive curr 334
U16 0 16 S -R - R
7.5 0
12.6 1
17.7 2
24.8 3
33 4
47 5
63 6
79 7
93 8
114 9
142 10
185 11
210 12
250 13
324 14
485 15
580 16
2.4 17
4 18
5.6 19
9.6 20
400 29
39 30
Continuous curr [A] 802 Float S S S
Ö
R--
Software version331Text
-- -
Ö
R--
Drivetype(AVy) 300 U16 - - 18 - R - R
Regulationmode 321 U16 03V/f control (3)
Ö
R/Z - -
Sensorless vect 0
Self-tuning 1
Field oriented 2
V/f control 3
Acc delta speed [FF] 21 U32 0
2
32
-1
100
Ö
R/W - -
Acc delta time [s] 22 U16 0 65535 1
Ö
R/W - -
Dec delta speed [FF] 29 U32 0
2
32
-1
100
Ö
R/W - -
BASIC MENU \ Drivetype
BASIC MENU
Parameter No Format
BASIC MENU