Part No. 40462 DPL-25S • DPL-30S • DPL-35S Super Series 7 - 3
September 2016 Section 7 - Repair Procedures
1-3
How to Check the Resistance of a
Valve Coil
The valve coil is located at the bottom of the
hydraulic lift cylinder.
1 Lower the platform, turn the machine off and
remove the key.
2 Connect the leads from an ohmmeter to the
valve coil terminals.
Valve coil specifications
Solenoid operated N.C. valve, 10V 7.8 to 9.5 Ω
BASE ASSEMBLY