Total Station Manual
91
ƻ
4
The window back to the
[Resection] window, and
press [F2] to set error limits.
[F2]
ƻ
5 Press [◄] \ [►] to turn on
the error limits status and use
the key []\[] to move
the focus down to input the
every error limit. Then press
[F4] (OK) to set and back to
the [Resection] window.
Input
error
limits
+
[F4]
ƻ
6 Press [F4] in [Resection]
window to start resection
measurement. It should be
input the station name and the
instrument high. Then press
[F4] (OK) go to next step.
[F4]
Input
name
and IH.
+
[ENT]
[F4]
ƻ
7 Set the first known point
and input prism high
DŽ
Ć
1
The title bar will display
the number of known points
in the current setting.
ƻ
8 Turn the instrument
telescope aimed at first point
and press [F1] to finish
current measurement.
Angle measurement: press
[F2] (REC) to record an
[F1]