Zoom80 | 162Technical Data
Aim360 accuracy
with the circular
prism
System accuracy
with Aim360
The accuracy with which the position of a prism can be determined with
Aim360 depends on several factors such as internal Aim360 accuracy,
instrument angle accuracy, prism type, selected EDM measuring program
and the external measuring conditions. The Aim360 has a basic standard
deviation level of ± 1 mm. Above a certain distance, the instrument angle
accuracy predominates and takes over the standard deviation of the
Aim360.
The following graph shows the Aim360 standard deviation based on
different prism types, distances and instrument accuracies.
Aim360 angle accuracy Hz, V
(std. dev. ISO 17123-3):
1 " (0.3 mgon)
Base Positioning accuracy (std.dev.): ± 1 mm