10 Technical data
10.1 SmartFan
Heat recovery rate Up to 91%
Level 1 Level 2 Level 3 Level 4
Airowineco-mode/ventilation
1)
[m³/h] 18 28 38 46
Sound pressure level [dB(A)] 11 19 28 33
Power consumption
2)
[W] 0,8 1,4 2,6 4,0
Power [V] 230 AC / 50-60 Hz
Input voltage [V] 12 DC SELV RS 485 AB
Type of protection IP 42
Software class A
Specicpowerinput
2)
[W/m³/h] min. 0,14
Standardised sound level difference D
n,w
[dB]
44/49 (with optional sound insulating)
Air intake free of aggressive gases, dust and oil
Permissible operating temperatures [°C] -20 ... 60
Diameter of the core hole [mm] 162
Minimum wall thickness
3)
[mm] 280
Optimal wall thickness [mm] 360 +
Size of the inside / outside cover [mm] 198 x 199 x 45 (WxHxD)
Weight [kg] 3,9
EnergyefciencyclassVO1254/2014
A
Conformity
1)
when operated in pairs
2)
without power supply
3)
with a shortened fan unit and a metal outside hood