WindObserver II Page 13 Issue 18
Doc. No. 1390-PS-0004 January 2009
Default Settings
The factory default settings are:
Non - heated units
A0 B3 C1 E1 F1 G0000 J1 K1 L1 M2 NA O1 P1 T1 U1 V1 X1 Y1 Z1
Heated units
A0 B3 C1 E1 F1 G0000 H1 J1 K1 L1 M2 NA O1 P1 T1 U1 V1 X1 Y1 Z1
Note that Heating (H command) is not enabled as a default condition. If heating is
required enabled then the H command must be set for H2.
See Section 9 Configuring for further details