EasyManua.ls Logo

Gill Instruments WindObserver II - Power supplies

Gill Instruments WindObserver II
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gill Instruments Ltd
_____________________________________________________________________________________________________________
________________________________________________________________________________________________
WindObserver II Page 20 Issue 18
Doc. No. 1390-PS-0004 January 2009
6.6. Power supplies
All WindObserver II units
Sensor Supply: -
Voltage 9 to 30v DC
Current 60mA max. 50mA average
The WindObserver II has reverse polarity protection.
Wind Observer II Units with Heating
Heater Supply: -
Voltage 22V to 30V (max) AC RMS or DC.
Current allow for 3A.
The AC Supply must be isolated from Mains Supply.
The heating module requires a separate power supply.
Heater Cable length should be minimised to avoid cable volt drops and ensure
maximum voltage received at the Anemometer.
The heating (H command) is not enabled as a default condition. If heating is
required enabled then the H command must be set for H2.
Each transducer is heated independently and will be active when ambient
temperature drops below approximately +15ºC each transducer will de-activate
when +25ºC threshold is reached.
The WindObserver II has reverse polarity protection.

Table of Contents

Related product manuals