6.6. Power supplies
All WindObserver II units
Sensor Supply: -
Voltage 9 to 30v DC
Current 60mA max. 50mA average
The WindObserver II has reverse polarity protection.
Wind Observer II Units with Heating
Heater Supply: -
Voltage 22V to 30V (max) AC RMS or DC.
Current allow for 3A.
The AC Supply must be isolated from Mains Supply.
The heating module requires a separate power supply.
Heater Cable length should be minimised to avoid cable volt drops and ensure
maximum voltage received at the Anemometer.
The heating (H command) is not enabled as a default condition. If heating is
required enabled then the H command must be set for H2.
Each transducer is heated independently and will be active when ambient
temperature drops below approximately +15ºC each transducer will de-activate
when +25ºC threshold is reached.
The WindObserver II has reverse polarity protection.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gill Instruments WindObserver II and is the answer not in the manual?

Gill Instruments WindObserver II Specifications

General IconGeneral
BrandGill Instruments
ModelWindObserver II
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals