EasyManua.ls Logo

Gill Instruments WindObserver II - Connecting to a Gill Winddisplay

Gill Instruments WindObserver II
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gill Instruments Ltd
_____________________________________________________________________________________________________________
________________________________________________________________________________________________
WindObserver II Page 26 Issue 18
Doc. No. 1390-PS-0004 January 2009
Connecting to a Gill WindDisplay
Refer to the WindDisplay User Manual for the method of operation.
Notes
Use the WindObserver II as supplied in the factory default settings – i.e. do not
reconfigure, apart from configuring heater if fitted. (See Section 9.5)
The WindDisplay can provide power for the WindObserver II.
WindObserver II
9 pair cable
WindDisplay
Signal names
Pair
no.
Colour
Cable – 2 or 3
twisted pairs
Signal
names
Terminal
nos.
TXB (+)
TXA (–)
1
green
black
TXD +
TXD –
RS422+
RS422-
CONNECTED INTERNALLY
Screen and
drain wires
Ground (Earth)
Supply V+
Supply V-
3
red
black
+
O
2
1
Heater + *
Heater - *
5
yellow
black
+
-
Heater power
supply
See Section 6.6
* If fitted