Appendix
28 Installation and maintenance instructions ENERGY 0020177748_03
Setting level Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.47 Outside temperature Current value Not
adjustable
d.50 Correction of the min-
imum fan speed
0 3000 rpm 1
Fan speed = Display value x 10
600 Adjustable
d.51 Correction of the max-
imum fan speed
-2500 0 rpm 1
Fan speed = Display value x 10
-1000 Adjustable
d.58 Solar circuit reheating 0 3 0 = Boiler's Legionella protection
function deactivated
3 = Hot water activated (target value
min. 60 °C)
0 Adjustable
d.60 Number of blocks by the
temperature sensor
Current value Not
adjustable
d.61 Number of successful
ignitions
Current value Not
adjustable
d.62 Night set-back 0 30 1 0 Adjustable
d.64 Average burner ignition
time
Current value s Not
adjustable
d.65 Maximum burner ignition
time
Current value s Not
adjustable
d.66 Activation of the warm
start function for hot water
off = Function deactivated
on = Function activated
1 Adjustable
d.67 Remaining burner anti-
cycling time (setting under
d.02)
Current value min Not
adjustable
d.68 Number of unsuccessful
ignitions at 1st attempt
Current value Not
adjustable
d.69 Number of unsuccessful
ignitions at 2nd attempt
Current value Not
adjustable
d.71 Maximum heating flow set
target temperature
45 80 1 75 Adjustable
d.75 Maximum cylinder reheat-
ing time
20 90 min 1 45 Adjustable
d.77 Max. cylinder reheating kW 1
Section "Technical data"
Adjustable
d.78 DHW max. flow temperat-
ure
50 80 1 Adjustable
d.80 Running time in heating
mode
Current value h Not
adjustable
d.81 Running time in DHW
mode
Current value h Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.83 Number of burner igni-
tions in DHW mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.84 Maintenance in 0 3000 h Number of hours = Display value x 10 300 Not
adjustable
d.85 Increase in the min. out-
put (heating and DHW mode)
kW 1
Section "Technical data"
Adjustable
d.90 Status of the eBUS room
thermostat
Current value off = Not connected
on = Connected
Not
adjustable
d.93 Setting the product code 0 99 1 Adjustable
d.94 Delete fault list 0 1 off = No
on = Yes
Adjustable
d.95 Software versions 1 = Main PCB
2 = Interface PCB
Adjustable
d.96 Reset to factory setting 0 = No
1 = Yes
Adjustable