EasyManuals Logo

Glow-worm EASICOM 3 25r User Manual

Glow-worm EASICOM 3 25r
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Appendix
0020177748_03 ENERGY Installation and maintenance instructions 33
G Wiring diagram, 30 kW
X14
L
N
X12
X51
X51
X20
16
1
9
3
15
4
5
6
13
X51
X20
X40 X51
X30
X21
X41
X22
X14
L
N
+
24V=
RT BUS
Burner
off
RT
X1
X106
X32
X12
X35
X1
RT
X21
L
N
L
N
1
5
eBUS
Burner off
X106
M
4
3
2
1
N
L
24V
230V~
24V
230V~
2
7
9
1
4
3
5
6
10
11
12
8
1 Main PCB
2 Interface PCB
3 Control system
4 Temperature sensor on the heating flow
5 Temperature sensor on the heating return
6 Fan
7 Gas valve assembly
8 Heating pump
9 Monitoring electrode
10 Room thermostat
11 Main power supply and connection for 230 V control
12 Ignition electrode