1 Safety
4 Installation and maintenance instructions ENERGY 0020177748_03
Notify the gas supply company or the Na-
tional Grid +44 (0) 800 111999 by tele-
phone once you are outside of the build-
ing.
1.4.3 Risk of death from escaping flue
gas
If you operate the product with an empty con-
densate trap / siphon, then flue gas may es-
cape into the room air.
In order to operate the product, ensure that
the condensate trap / siphon is always full.
1.4.4 Risk of death due to blocked or
leaking flue gas routes
Installation errors, damage, tampering, unau-
thorised installation sites or similar can cause
flue gas to escape and result in a risk of pois-
oning.
What to do if you smell flue gas in the prop-
erty:
Open all accessible doors and windows
fully to provide ventilation.
Switch off the product.
Check the flue gas routes in the product
and the flue gas diversions.
1.4.5 Risk of poisoning and burns caused
by escaping hot flue gases
Only operate the product if the air/flue pipe
has been completely installed.
With the exception of short periods for
testing purposes, only operate the product
when the front casing is installed and
closed.
1.4.6 Risk of death due to explosive and
flammable materials
Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).
1.4.7 Risk of death from electric shock
There is a risk of death from electric shock if
you touch live components.
Before commencing work on the product:
Disconnect the product from the power
supply by switching off all power supplies
at all poles (electrical partition with a con-
tact gap of at least 3 mm, e.g. fuse or cir-
cuit breaker).
Secure against being switched back on
again.
Wait for at least 3 minutes until the capa-
citors have discharged.
Check that there is no voltage.
1.4.8 Risk of death due to lack of safety
devices
The schematic drawings included in this doc-
ument do not show all safety devices re-
quired for correct installation.
Install the necessary safety devices in the
system.
Observe the applicable national and inter-
national laws, standards and guidelines.
1.4.9 Risk of corrosion damage due to
unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the flue
system.
Ensure that the supply of combustion air is
always free of fluorine, chlorine, sulphur,
dust, etc.
Ensure that no chemical substances are
stored at the installation site.
If you are installing the product in
hairdressing salons, painter's or joiner's
workshops, cleaning businesses or similar
locations, choose a separate installation
room in which the room air is technically
free of chemical substances.
1.4.10 Risk of material damage caused by
frost
Do not install the product in rooms prone
to frost.
1.4.11 Risk of being burned or scalded by
hot components
Only carry out work on these components
once they have cooled down.