3-24
USER HANDBOOK
• Press and hold ‘YES’ (Bottom Button) for one
second to zero all ranges and return to live
readings.
Alternatively,
• Press and hold ‘NO’ (Top Button) for one
second to return to live readings without zeroing.
3.17 Datalogging
The SHIPSURVEYOR can store over 1000 logged entries in
date order. In addition, it can store up to 300 location entries.
Location (LOC) entries allows logged data to be associated
with particular areas of the vessel.
3.17.1 CSM Mode
The instrument, by default, has automatic and manual
datalogging enabled when operating in CSM mode.
During automatic datalogging the instrument stores the
values of all gas ranges together with the current time and
date at 60 second intervals. This interval can be set between
1 second and 10 minutes.
Manual datalogging allows the user to store a snapshot
reading at any time.
To manually store a reading:
• Press and hold ‘STORE’ (Top Button) for one
second.