Setup
28 332305J
Priming
NOTE: It is not necessary to prime pump every time
pump is filled with lubricant.
Pump only requires priming the first time it is used or if it
is allowed to run dry.
1. Loosen pump element fitting (F
IG. 31).
NOTE: When loosening pump element fitting, do NOT
loosen pump element. Loosening pump element will
change the output volume
2. Only run pump until air is no longer dispensed with
the lubricant coming out of element fitting (F
IG. 32).
3. Tighten pump element fitting using two wrenches
working in opposite directions (F
IG. 31).
F
IG. 31
FIG. 32