Advanced Programming
56 332305J
3. Press the ENTER button.
A11- Warning Off Through Alarm Relay
This function changes the behavior of the alarm output
in a warning condition to always off.
Fault and Warning LEDs Illuminate
1. The default OFF is
displayed. The alarm
output will turn on
during a warning
condition.
2. Press the UP or DOWN
ARROW to change OFF to
ON on the display to change
the alarm output to be off
during a warning condition.
3. Press the ENTER button to exit
Advanced Programming.
Models with Firmware 6.06 and
later for non-DMS models.
Models with Firmware 7.09 and
later for DMS models
A12 - Prelube Sequences
This function changes the behavior of the prelube func-
tion to add more lubrication sequences upon pump start
up. While running multiple sequences, after the initial
sequence, PL:xx will be displayed showing how many
sequences are left.
Note: if pump has option “08” and using a pressure
switch with multiple sequences, a vent delay time must
be programmed under Advanced Programming Option
A3.
Prelube LED illuminates (F
IG. 42)
1. The default 0001 is displayed.
When Prelube is on, it will run
one sequence.
2. Press the UP or DOWN
ARROW button until desired
number of prelube
sequences displays.
F
IG. 43
FIG. 44