Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Moduledoesnot
havesoftware.
Insertasystemtokeninto
theADMmoduleandcycle
thepower.Waituntilthe
uploadiscompletebefore
removingthetoken.
Dialsettowrong
position.
EnsuretheHCMdialisset
tothecorrectposition:
H-30=0
H-40=1
H-50=2
H-XP2=3
H-XP3=4
No24VDCsupply
tomodule.
Greenlightoneachmodule
shouldbelit.Ifgreenlightis
notlit,checktomakesure
eachCANcableconnection
istight.Verifythepower
supplyisoutputting24
VDC.Ifnot,checkpower
supplywiring.Ifwiringis
okay,replacethepower
supply.
CACMHCMHCMCommunica-
tionError
Looseorbroken
CANcable.
ChecktheCANcables
runningbetweenGCA
modulesandtightenof
needed.Iftheproblem
stillpersistsmoveeach
cablearoundtheconnector
andwatchthe󰘱ashing
yellowlightontheGCA
modules.Iftheyellowlight
stops󰘱ashing,replacethe
CANcable.
334946C 19