Troubleshooting
Hydraulic Hydraulic
Hydraulic
Drive Drive
Drive
System System
System
Beforeperforminganytroubleshootingprocedures:
1.FollowPressureReliefProcedure,page48.
2.TurnmainpowerOFF.
3.Allowequipmenttocool.
Trytherecommendedsolutionsintheordergivenfor
eachproblem,toavoidunnecessaryrepairs.Also,
determinethatallcircuitbreakers,switches,and
controlsareproperlysetandwiringiscorrectbefore
assumingthereisaproblem.
Note
Motorstartupisdelayedamaximumof5
secondsfromthelasttimethemotorwas
turnedofftoreducethechanceofthemotor
overheating.
PROBLEM PROBLEM
PROBLEM
CAUSE CAUSE
CAUSE
SOLUTION SOLUTION
SOLUTION
Looseconnectionsand/orcontactor
(CT01)isnotclosing.
Checkwiringbetweenthefollowing
components:
HCMandcontactorCT01
HCMandfusesF11/F12
DamagedHCM.ReplaceHCM.
Looseconnectionsand/orcontactor
(CT01)isclosing.
Checkwiringbetweenthefollowing
components:
motorjunctionboxandCB12
CB12
contactCT01andmain
disconnectswitch(orterminal
blocksTB06andTB09)
Electricmotorwillnotstartorstops
duringoperation.
Circuitbreakertripped.ResetCB12withintheelectrical
enclosureaftercon󰘰rmingwiringis
correctanditsinsulationisintact.
334946C 37