Repair
Replace Replace
Replace
Electric Electric
Electric
Motor Motor
Motor
Remove Remove
Remove
NOTICE NOTICE
NOTICE
Topreventdroppingtheelectricmotor,twopeople
mayberequiredtoremovethemotorfromthe
system.
1.FollowShutdown,page49.
2.Openelectricalenclosure.Disconnectthe
AsideheaterconnectorfromtheTCM.See
ElectricalSchematics,page94.Closethe
electricalenclosuredoor.
3.Removemountingboltsfromthebottomframe
andmovethesystemawayfromthewall.
Figure2
4.Removeupperbolts(3).Tilttheelectrical
enclosuredowntogainaccesstothemotor
cover.
5.Removemotorandbeltcovers(123,131,132).
Liftcover(132)andloosenthebluebracket(131)
fasteners.Liftthebluebracket(133)offofthe
fastenersandsetaside.Removethebeltcovers
(131,132).
Figure3MotorandBeltCovers
Figure4HeaterandBeltCovers
54 334946C