Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
L1AXADM
LowChemicalLevel
A
Lowmateriallevel.
Re󰘰llmaterialandupdate
drumlevelonADM
Maintenancescreen.
Alarmcanbedisabledon
theSystemSetupscreen.
L1BXADM
LowChemicalLevel
B
Lowmateriallevel.
Re󰘰llmaterialandupdate
drumlevelonADM
Maintenancescreen.
Alarmcanbedisabledon
theSystemSetupscreen.
MMUX
USB
MaintenanceDue-
USB
USBlogshave
reachedalevel
wheredataloss
willoccuriflogsare
notdownloaded.
InsertaUSBdriveintothe
ADManddownloadalllogs.
Pressure
differencebetween
AandBmaterial
isgreaterthanthe
de󰘰nedvalue.
Ensurematerial󰘱owis
equallyrestrictedonboth
materiallines.
Pressure
imbalanceis
de󰘰nedtoolow.
Ensurethatthepressure
imbalancevalue,onthe
SystemSetupscreen,isat
anacceptablemaximum
pressuretoprevent
unnecessaryalarmsand
abortdispenses.
Outofmaterial.
Filltankswithmaterial
Fluidleakingfrom
heaterinletrupture
disk.
Checkifheater
andPRESSURE
RELIEF/SPRAYvalveare
plugged.Clear.Replace
rupturedisk.Donotreplace
withapipeplug.
P0AX
HCM
PressureImbalance
AHigh
Feedsystem
defective.
Checkfeedpumpand
hosesforblockage.Check
thatfeedpumpshave
correctairpressure.
22