Loading...
Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Disconnectedor
looseRTDcableor
connection.
Checkallwiringand
connectiontoRTD.
T6DBHeaterB
SensorErrorB
BadRTD.
SwitchtheRTDwith
anotherandseeiftheerror
messagefollowstheRTD.
ReplaceRTDiftheerror
followstheRTD.
T6DHHose
SensorErrorHose
Disconnectedor
shortedRTDcable
inhoseorbadFTS.
ExposeeachhoseRTD
connectiontocheckand
retightenanyloosecon-
nector.MeasurehoseRTD
cableandFTScontinuity.
SeeRepairHeatedHose,
page60.OrderRTDTest
kit24N365formeasure-
ment.
DisconnecthoseRTDand
usemanualhosemodeto
󰘰nishjobuntilrepaircanbe
completed.
ShortedRTDcable
inhoseorFTS.
ExposeeachhoseRTD
connectiontocheckfor
exposedandshortedRTD
wires.MeasurehoseRTD
cableandFTScontinuity.
SeeRepairHeatedHose,
page60.OrderRTDTest
kit24N365formeasure-
ment.
DisconnecthoseRTDand
usemanualhosemodeto
󰘰nishjobuntilrepaircanbe
completed.
T6DT
TCM
SensorErrorTCM
ShortedAorB
HeaterRTD
Iftheerrorstilloccurswith
thehoseFTSunplugged,
oneoftheheaterRTDs
isbad.UnplugtheAor
BRTDfromtheTCM.If
unplugginganRTD󰘰xes
theT6DTerror,replacethe
RTD.
334946C 33