Troubleshooting
Graco Graco
Graco
InSite InSite
InSite
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
TurnReactorON.
Ensureunitisproperlyinstalled.
Verify24Vatoutputofthepower
supply.
NomodulestatusLEDsare
illuminated.
Nopowertocellularmodule.
MakesuretheM8,4–pintoM12,
8–pincableisinstalledbetween
cellularmoduleandpowersupply.
Stillidentifyinglocation.Waitafewminutesfortheunitto
identifythelocation.
Movesystemtoalocationwitha
clearviewofthesky.
HasnotidentiedGPSlocation
(greenmodulestatusLED
ashing).
Unabletoidentifylocation.Ina
locationwhereGPSlockcannot
occur.Buildingsandwarehouses
oftenpreventGPSlocks.
Useextensioncable16X521and
movecellularmoduletoalocation
withaclearviewofthesky.
Stillestablishingcellular
connection.
Waitafewminutesfortheunitto
establishtheconnection.
Movesystemtoalocationwith
cellularservicetoestablishcellular
connection.
Hasnotestablishedcellular
connection(orangemodulestatus
LEDashing).
Unabletoestablishcellular
connection.
Useextensioncable16X521and
movecellularmoduletoalocation
withaclearviewofthesky.
Cannotviewdataformyunit(s)on
website.
GracoInSiteunithasnotbeen
activated.
Activateunit.SeeRegistering
andActivatingtheGracoInSite
section.
Temperaturedatanotdisplayed
onwebsite.
Reactortemperature
measurementisnotworking.
SeeSystemtroubleshooting
section.
Hosezonetemperaturedatanot
displayedonwebsite.
TheRTDorthermocoupleisnot
correctlyinstalledonthehoseor
isbroken.
SeeRTDorThermocouplerepair
section.
Pressuredatanotdisplayedon
website.
Reactorpressuremeasurementis
notworking.
SeeSystemtroubleshooting
section.
334946C