Operation
Spray Spray
Spray
1.Engagethegunpistonsafetylockandclose
gunuidinletvalvesAandB.
Fusion Fusion
Fusion
Probler Probler
Probler
2.Attachthegunuidmanifold.Connectthe
gunairline.Opentheairlinevalve.
3.Adjustthegunairregulatortodesiredgun
airpressure.Donotexceedthemaximum
ratedairpressure.Seeyourgunmanual,
RelatedManuals,page3.
4.Setthepressurerelief/sprayvalves(SA,SB)
tospray
.
W
W
LL EE
5.Verifytheheatzonesareonand
temperaturesareontarget.
6.Opentheuidinletvalvelocatedateach
pumpinlet.
W
WLL DD
7.TapthePump Pump
Pump
Mode Mode
Mode
button.
8.SelectSpray Spray
Spray
modefromthedropdown
menu.
9.If If
If
using using
using
pneumatic pneumatic
pneumatic
transfer transfer
transfer
pumps, pumps,
pumps,
turnon
airtothetransferpumps.Seeyourpump
manual,RelatedManuals,page3.
10.Tap
toturnonthemotor.
NOTE: NOTE:
NOTE:
Electrictransferpumpswill
automaticallyturnonwiththemotor.
11.Checktheuidpressuregauges(GA,GB)
toensureproperpressurebalance.If
imbalanced,reducepressureofhigher
componentbyslightlyturningthepressure
relief/sprayvalveforthatcomponenttoward
pressurerelief/circulationuntilthe
gaugesshowbalancedpressures.
W
WLL EE
3A8500A 37

Other manuals for Graco Reactor 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 3 and is the answer not in the manual?

Graco Reactor 3 Specifications

General IconGeneral
BrandGraco
ModelReactor 3
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals