AdvanceDisplayModule(ADM)
Heat Heat
Heat
UsetheHeatscreentocalibratehoseheatand
setthehosecontrolmode.Tocalibratethe
system,seetheCalibration,page38.
Setting Setting
Setting
Description Description
Description
HoseControl
Mode
Taptoselecthosecontrolmode.
FTS: FTS:
FTS:
controltotargettemperatureusing
anFTS(uidtemperaturesensor)on
eachsideofthehose.Calibrationis
requiredtouseFTScontrolmode.See
CalibrationProcedure,page38.
Resistance: Resistance:
Resistance:
controltotarget
temperatureusingtheresistance
oftheheaterelement(changeswith
temperature).Calibrationisrequired
touseResistancecontrolmode.See
CalibrationProcedure,page38.
Manual: Manual:
Manual:
controltotargetcurrent(amps)
toheatthehose.Manualcontrolmode
hasnopre-programmedcontrolandis
designedtobeusedforalimitedamount
oftimeuntilapropercalibrationcanbe
performedorFTSissuescanberesolved.
NOTE: NOTE:
NOTE:
Whenmanualhosemodeis
enabled,themanualhosemodeadvisory
(EVCH)willappear.
HoseA
Calibration
Factor
Resistancevaluedeterminedduringthe
calibrationprocessfortheAsidehose.
HoseB
Calibration
Factor
Resistancevaluedeterminedduringthe
calibrationprocessfortheBsidehose.
Last
Calibration
Date
Date/timeoflastsuccessfulcalibration.
EnablePower
Management
Tapthecheckboxtoenable/disable
powermanagement.Tapthenumberto
adjusttheprimaryheaterpowerlimit.
Powermanagementallowsusersto
limittheprimaryheaterwattagetoa
desiredlevel.Thiscanbedonetofree
upauxiliarypowerforotherdevices
onageneratorand/orrunthesystem
onasmallergenerator.Withpower
managementenabled,thenewtotal
systemloadcanbedeterminedusingthe
formulabelow:
TotalSystemLoad(withpower
management)=TotalSystemLoad
(withoutpowermanagement)
(PrimaryHeaterLoad(withoutpower
management)PrimaryHeaterLoad
(withpowermanagement))
Example:EliteE-2010kW
Powermanagementenabledandprimary
heaterlimitsetto7kW
TotalSystemLoad(withpower
management)=15kW(10kW7kW)
=12kW
NOTE: NOTE:
NOTE:
Onsinglephasesystems,peak
currentdrawisreducedandlinearly
scaleswiththedropintotalsystemload.
Onthreephasesystems,peakcurrent
drawdoesnotscalelinearlywiththe
dropintotalsystemload.
Enable
Maximum
Temperature
Setpoint
Tapthecheckboxtoenable/disable
auserdenedmaximumtemperature
setpoint.Tapthenumbertoadjustthe
maximumtemperaturesetpointthatcan
beenteredonthehomescreen.
Enable
Minimum
Temperature
Setpoint
Tapthecheckboxtoenable/disable
auserdenedminimumtemperature
setpoint.Tapthenumbertoadjustthe
minimumtemperaturesetpointthatcan
beenteredonthehomescreen.
48 3A8500D