EasyManuals Logo

GRAUPNER POLARON EX-1400 User Manual

GRAUPNER POLARON EX-1400
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
English
INNOVATION & TECHNOLOGIE
18
19
Adjustable Parameters
NiCd, NiMH batteries
Parameter Short description
Current The default value, inherited from the “Proles” menu to 1C, can be adapt-
ed within the “Maximum capacity” of the charge port rate and the charger
features, see display 2 of the menu “Settings” on page 43, in the range of
0.1 to a maximum of 30 A.
Delta Peak Sensitivity adjustment of the delta Peak in mV per cell. Default: 5 mV /
cell NiMH (Setting range: 0 ... 15 mV) and NiCd 7 mV / cell (range: 5 ...
25 mV)
Trickle charge OFF, 50 to 500 mA in 50 mA steps, AUTO (default value: OFF)
Maximal tempera-
ture
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
peratures is exceeded.
Maximal capacity Setting range: 10 ... 150% in 5% increments, OFF (default value:
120%). To avoid damage from overcharging, the charge stops when the
limit is exceeded.
Safety timer Setting range: 10 ... 900 minutes in 5 minute increments OFF (de-
fault value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.
LiFe, LiIo and LiPo batteries
Parameter Short description
Voltage Maximum cell voltage at constant charge (CV)
Current The default value, inherited from the „Proles“ menu to 1C, can be ad-
apted within the „Maximum capacity“ of the charge port rate and the
charger features, see display 2 of the menu „Settings“ on page 43, in the
range of 0.1 to a maximum of 30 A.
Maximal tempera-
ture
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
peratures is exceeded.
Maximal capacity Setting range: 10 ... 150% in 5% increments, OFF (default value:
120%). To avoid damage from overcharging, the charge stops when the
limit is exceeded.
Safety timer Setting range: 10 ... 900 minutes in 5 minute increments OFF (de-
fault value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.

Other manuals for GRAUPNER POLARON EX-1400