0.0mΩ
1N 4.116VAUTO
4.116Vc
0.040Vr
1N 2N 3N 4N
5N
6N
8N
7N
4.116v 4.116v 0.000v
Balance
Once the bars are at the same height both in the icon on the top left and in the
graphic, the process is complete.
After completion of the balance program, tap the STOP eld at the bottom of
the display. Now you can switch the INC / DEC buttons again between the dis-
play of “BALANCE” menu or exit by pressing the ESC key, the menu towards
the basic display.
Menu DATA
This “DATA” menu is a pure info menu, in which you read the data before completion of charge
and discharge program, but cannot change anything. Signicantly more detailed information,
please check the download area of the product “PC software for Polaron Chargers”.
To prevent sparking when connecting batteries, CH1 and CH2 battery terminals are provi-
ded with a capacitor, voltage in the line „output“ is displayed while another battery is
connected.
Parameter Short description
Input Voltage of the power supply device
Output Voltage of the devices connected to the respective output
battery packs or optionally display the charging voltage of
the buffer capacitor
Batt.Temp. Battery temperature measured by a temperature sensor, if
connected
Max.Temp. Maximum battery temperature measured by a temperature
sensor, if connected
Resistance Internal resistance of the battery pack connected to the
respective output
Input voltage Input voltage
Tapping the DEC button (down arrow) at the bottom of the screen brings to the second page of the
„DATA“ menu:
Parameter Short description
Cycle Nr: Number of the charge / discharge displayed cycle
00:00:00 duration of the charging and discharging of the displayed
cycle
0.000Vp Voltage peak (maximum voltage reached)
0.000Va Voltage average (medium voltage
0mAh Charged or discharged capacity
0.0mΏ Internal resistance determined by the charger
PM 05:12:59