EasyManua.ls Logo

GRAUPNER POLARON EX-1400 - Page 27

GRAUPNER POLARON EX-1400
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
INNOVATION & TECHNOLOGIE
26
27
PM 01:26:08
DISCHG
NORMAL
CH1 CH2
13 LiPo 03s 2200
0.0°C
00:01:56
67mAh
11.678V 2.20A
11.97Vin 34.5m
STOP
STOP
11,789Vc 0,067Vr
After the lapse of the aforementioned 5 seconds or if necessary, after a manu-
al start, discharge process is begun. Otherwise, an error message is shown.
Note:
Tap the image to go directly to the „data display“, see page 35.
PM 01:26:08
DISCHG
NORMAL
CH1 CH2
13 LiPo 03s 2200
0.0°C
00:01:56
67mAh
11.678V 2.20A
11.97Vin 34.5m
STOP
STOP
11,789Vc 0,067Vr
1
2
3
4
5
6
7
8
9
10
1 Discharge mode
2 Actual discharge time
3 Battery temperature (Only with sensor)
4 Discharged capacity
5 Actual discharging voltage
6 Actual discharge current
7 Actual voltage of the power supply
8 Internal resistance of the battery
9 Vc = Voltage center (the center line voltage value actually assigned)
Vr = Voltage range (vertical range of the voltage display)
10 History of the discharging voltage
PM 02:26:23
DISCHG
NORMAL
CH1 CH2
13 LiPo 03s 2200
0.0°C
00:02:11
72mAh
11.673V 2.20A
11.97Vin 34.5m
STOP
STOP
1.0A
3.0A
Set Current
15.0A
5.0A
10.0A
20.0A
To change the actual discharge current tap the display to the actual discharge
current (6). In the lower half of the display appears a selection window.
PM 02:26:28
DISCHG
NORMAL
CH1 CH2
13 LiPo 03s 2200
0.0°C
00:02:16
74mAh
11.672V 1.80A
11.97Vin 34.5m
STOP
STOP
1.0A
3.0A
Set Current
15.0A
5.0A
10.0A
20.0A
Increase or decrease now by using the INC / DEC buttons to select the current
value, such as 1.80 A. If necessary, you can also specify a value that strongly
deviate from the current value by touching one of the six option buttons.
Tapping the
eld closes the window and takes the selected value into the
memory.