85
access the various different parameters. The active parameter is always the
middle parameter and is indicated by a flashing “
:
”. The entire TGRP menu
is shown below:
TGRP Parameter Options Description
Scan Lists
On or Off for Scan
Lists 1-22
Sets membership in Scan Lists.
Use
3 4
keys to scroll through
Scan Lists. Use SEL key to toggle
Scan List membership. A “
*
” next
to the Scan List number indicates
that the object is mapped to that
Scan List.
TSYS
New or previously
stored trunking sys-
tem object (TSYS)
To enter a new trunking system,
use the
34
keys to scroll through
the stored systems until
N E W
appears, then press SEL to enter
the parameters for the new TSYS.
To use a trunking system that you
have previously entered, use the
34
keys to scroll to the desired
system.
ID
Decimal, hex or AFS
depending on TSYS
type
The digital address of the talkgroup
or individual radio ID on the trunked
radio system.
Type Group or Private
Use Group for talkgroup ID, Private
for individual radio ID.
Tag Alpha-numeric text
The alphanumeric display name
for the TGRP. Use the standard text
entry method or QTXT to name the
object.
L/Out On or Off
Permanent lockout for the TGRP.
Also accessed by pressing FUNC
L/OUT while the scanner is stopped
on the TGRP object.
Priority On or Off
Turns Priority Mode on or off for the
TGRP object.
LED Mode Solid or Flash
Controls whether the ALERT LED
flashes or remains on solid when
the ALERT LED is used.
LED Color 0-7
Sets LED color to 0-7 as defined in
the GLOB menu. By default, 0=LED
Off, 1=Red, 2=Yellow, 3=Green,
4=Cyan, 5=Blue, 6=Magenta,
7=White.