Applying wildcard lockout to an undesired talkgroup creates a new TGRP
object in the same Scan List as the wildcard TGRP, then applies permanent
lockout to the new TGRP object, so that will be ignored in the future by the
scanner when scanning the wildcard talkgroup. To unlock or edit talkgroups
locked out using the wildcard lockout feature, press PGM, then navigate to
the object using the 5-way pushbutton pad. Press FUNC, then L/OUT to re-
move permanent lockout from the talkgroup. Press FUNC, then CL to delete
the TGRP object from the scanner. Press the
EDIT
, then the
CURR
softkey
to edit and save the TGRP object.
Setting the Default Scan List
By default, your scanner will store all new objects, and objects found during
Search, Tune, and Sweeper as mapped to Scan List 01.
You can easily change the default Scan List to any Scan List you specify, in-
cluding the special FAV and SKYWARN Scan Lists.
Press PGM, then the
GLOB
softkey, and use the
6
key to scroll down until
the
Dflt ScanList
item appears in the middle of the display. Enter a
new Scan List number to use as the default Scan List. The following num-
bers are valid:
0: The “not scanned” (ns) Scan List - objects that have no Scan List map-
pings can be found here
1-20: The twenty normal Scan Lists
21: The FAV Scan List
22: The SKYWARN Scan List.
Press ENT or the
Done
softkey to store your new default Scan List value,
then press the
SAVE
softkey to save your changes to the radio's configura-
tion memory.
Deleting Objects
Objects that you no longer need to use can easily be deleted from the PSR-
310's memory, making room for new objects.
To delete an object, press PGM, then use the
3456
keys to navigate
to the object you wish to delete. Press FUNC CL to delete the object. The
scanner will ask you to confirm the delete command before removing the
object from the scanner's memory. Deletions cannot be un-done.
To delete a TSYS, use the FIND feature to search for the TSYS by name.
Press PGM, then press the
EDIT
softkey, then press the
FIND
softkey,
and use the Standard Text Entry Method to enter all or part of the TSYS
name you wish to delete. Press the
OK
softkey to begin searching, and, if
necessary, press the
NEXT
softkey to continue searching until the desired
TSYS is located. Once the TSYS has been located, press the PGM key, then