93
Channels
56
to scroll,
34
to
toggle on/off
Toggle search channels when Ma-
rine, CB, FRS/GM/MURS search
are used.
Tag Alpha-numeric text
The alphanumeric display name for
the SRVC search. Use the standard
text entry method or QTXT to name
the object.
L/Out On or Off
Permanent lockout for the SRVC
object. Also accessed by pressing
FUNC L/OUT while the scanner is
stopped on the SRVC object.
LED Mode Solid or Flash
Controls whether the ALERT LED
flashes or remains on solid when
the ALERT LED is used.
LED Color 0-7
Sets LED color to 0-7 as defined in
the GLOB menu. By default, 0=LED
Off, 1=Red, 2=Yellow, 3=Green,
4=Cyan, 5=Blue, 6=Magenta,
7=White.
Latch LED On or Off
Normally the ALERT LED is active
only while the object is receiving a
transmission. When Latch is on, the
ALERT LED will remain lit after the
transmission is complete, unless
overridden by a subsequent object
that is also using the ALERT LED.
Backlight On, Off or Flash
Controls whether the backlight
should be on, off or flashing while
the object is active.
Alarm
None, Chirp, Hi-Lo,
Alert, Ring, 2-Chirp,
Fast Hi-Lo, DTMF#
Sets the Audible Alarm for the
SRVC object. When an Audible
Alarm is selected, the selected
alarm will play anytime the scanner
stops for activity on the SRVC ob-
ject while scanning.
Fav Yes or No
When Yes, the SRVC object is a
member of the Favorites Scan List.
EXPERT BELOW
Modulation AM, FM, NFM, Auto
Modulation setting for the SRVC
search. In most cases Auto will
work fine. Use AM to override and
force AM modulation, FM to force
FM modulation, NFM to force nar-
row FM modulation.