Greenlee Textron / Subsidiary of Textron Inc.
10
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
855 Smart Bender™
Operation — Standard Pendant (cont’d)
Stub Up and Offset Bending Chart to determine
bending marks when using standard pendant.
CONDUIT SIZE 1/2 3/4 1 1-1/4 1-1/2 2
DEDUCT 7-1/2 9 11 13-5/8 14-7/8 16-3/8
MINIMUM STUB 9-1/2 11 13 15-5/8 16-7/8 18-3/8
DEDUCT 7-1/2 9 11 13-5/8 14-7/8 16-1/8
MINIMUM STUB 9-1/2 11 13 15-5/8 16-7/8 18-1/8
OFFSET-“X” 2-1/2 3-1/16 3-1/16 4 4-3/4 4-3/4
EMT
IMC, RIGID
& PVC
Finished Angle
15° 30° 45°
OFFSET MAX CENTER MAX CENTER MAX CENTER
CONDUIT TO CONDUIT TO CONDUIT TO
SIZE CENTER SIZE CENTER SIZE CENTER
2 3/4 7-3/4
4 1-1/2 15-7/16 3/4 7-15/16
6 2 23-3/16 1 11-15/16 1/2 8-5/16
8 2 30-7/8 1-1/2 15-15/16 1 11-1/16
10 2 38-5/8 2 19-15/16 1-1/4 13-13/16
12 2 46-3/8 2 23-15/16 1-1/2 16-5/8
14 2 54-1/16 2 27-15/16 2 19-7/16
16 2 61-13/16 2 31-15/16 2 22-1/4
18 2 69-9/16 2 35-15/16 2 25-1/16
20 2 77-1/4 2 39-15/16 2 27-15/16
22 2 85 2 43-15/16 2 30-3/4
STUB LENGTH
STUB
LENGTH
MARK
BENDING
MARK 1
DEDUCT
STUB
LENGTH
MARK
BENDING
MARK 1
STUB LENGTH
BENDING
MARK 1
BENDING
MARK 2
START OF BEND
CENTER TO CENTER
X
C
E
N
T
E
R
T
O
C
E
N
T
E
R
BENDING
MARK 1
BENDING
MARK 2
START OF BEND
X