27
6.2 Indirect calibration
A value from the following table is to be added to the
default factory calibration value in the display. To
reset the pump to the factory calibration value, acti-
vate the "DEFAULT" function, see section 4.17.
To use the values, the following must be fulfilled:
The viscosity and density of the liquid to be dosed
must not differ considerably from water at 68 °F
(20 °C).
A Grundfos installation kit or corresponding foot
valve, injection valve and hose diameter must be
used.
The length of the dosing hose must not exceed
20 feet.
The suction lift must be between 4 inches and
5 feet.
Adding the value:
Fig. 25 Adding a table value to the default factory calibration value
Pump type
Values to be added to the calibration value at various pressures [psi]
0.0-
14.5
14.5-
29.0
29.0-
43.5
43.5-
58.0
58.0-
72.5
72.5-
87.0
87.0-
116
116-
145
145-
174
174-
203
203-
232
232-
261
DME 2 1.4 1.1 0.8 0.5 0.2 –0.2 –0.6 –1.2 –1.8 –2.4 3.0 –3.6
DME 8 3.52.72.01.20.40.41.63.1––––
DME 12 2.11.30.40.41.32.13.4–––––
DME 19 18.3 12.2 6.1 0 –6.1 –12.2 –21.4 ––––
DME 48 24.38.38.3–––––––––
Operating display
without changes
Operating display
Set value
to table value
+ display value
Grundfos.bk Page 27 Wednesday, May 21, 2008 11:21 AM