3.3.1.2 Temperature ranges
The following temperature ranges and humidity apply:
Product life phase Temperature range Air humidity
Transport -10 to +60 °C
Operation -20 to +70 °C Up to and at 85 %,
condensation forma-
tion is not permissible
Storage -10 to +40 °C Up to 75 %
Table3-2 Temperature ranges: FlexxPump
3.3.1.3 IP protection class
The product conforms to the protection class IP65.
3.3.1.4 Operating pressure
The operating pressure is 70 bar and is monitored electronically by counter-
pressure measurement.
3.3.2 Splitter
3.3.2.1 Temperature ranges
The following temperature ranges and humidity apply:
Product life phase Temperature range Air humidity
Transport -10 to +60 °C
Operation +10 to +80°C Up to and at 85 %,
condensation forma-
tion is not permissible
Storage -10 to +40°C Up to 75 %
Table3-3 Temperature ranges: Splitter
3.3.2.2 Accuracy of the lubricant distribution
The accuracy of the lubricant distribution is ±10%. The accuracy is valid up to
a pressure difference of less than 6 bar.