5.4.7.2 Basics
Average lubricant
requirement at a
lubrication point
(U)
The following lubricant quantities should be dispensed at least per lubrication
point. These are empirical values from Güdel. These values can be met only
approximatively due to the number of outputs of the pumps and the installed
splitters.
Size Average lubricant requirement
per lubrication point (U)
1-5 0.30cm
3
/ 100km
6-7 0.40cm
3
/ 100km
Table5-4 Average lubricant requirement per lubrication point (U)
Recommended lu-
brication quantity
(P
t
)
The recommended lubrication quantity P
t
can be found in the following table.
System Size 1-5 Sizes 6-7
3 lubrication points
(e.g. EP, TMF, TMO)
0.9cm
3
/ 100km 1.2cm
3
/ 100km
6 lubrication points
(e.g. ZP)
1.8cm
3
/ 100km 2.4cm
3
/ 100km
4 lubrication points
(e.g. X-axis FP)
1.2cm
3
/ 100km 1.6cm
3
/ 100km
Table5-5 Recommended lubrication quantity (P
t
)
5.4.7.3 Minimum lubrication quantity
Splitters only function correctly if > 0.5 cm
3
of lubricant is produced at their
input per lubrication cycle.
Commissioning
OPERATING MANUAL Automatic lubrication system