Replace the cartridge as follows:
1 Remove the vent locking mechanism in the direction of the arrow
2 Switch off FlexxPump
3 Remove the covering by turning in the direction of the arrow
4 Remove empty cartridge
5 Remove the retaining cover from the new cartridge
6 Lubricate the O-ring slightly
7 Insert new cartridge (make sure the cartridge fits in properly)
8 Put on the covering and turn hand-tight in the direction of the arrow
9 Switch on the FlexxPump
10 Insert vent locking mechanism and secure
11 Check the lubrication system Ü275
The cartridge is replaced.