3-11
Figure 3-14 Effect diagram of front mounting bracket and guide rail installation
(1) Rear panel (2) Guide rail
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the purpose of heat
dissipation.
Mounting the Switch on a Workbench
In many cases, standard 19-inch racks are not available. Therefore, switches are often placed on clean
workbenches. To place your switch on a workbench, you simply need to:
z Make sure that the workbench is clean, flat, and sturdy.
z Make sure that the environment is well ventilated and allows 10 cm (3.94 in.) of space around the
chassis for heat dissipation.
z Do not place heavy objects on your switch.
z The vertical distance between two switches must be at least 1.5 cm (0.59 in).
Connecting the Grounding Cable
z Correctly connecting the chassis grounding cable is crucial to the lightning protection and
electromagnetic susceptibility (EMS) of a switch.
z The power and grounding terminals in this section are for illustration only.
The power input end of the switch is connected with a noise filter, whose central ground is directly
connected to the chassis, forming the so-called chassis ground (commonly known as PGND). This
chassis ground must be securely connected to the earth so that the faradism and leakage electricity can
be safely released to the earth, enhancing the EMS capability of the switch.

Table of Contents

Other manuals for H3C S5500-EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5500-EI Series and is the answer not in the manual?

H3C S5500-EI Series Specifications

General IconGeneral
BrandH3C
ModelS5500-EI Series
CategorySwitch
LanguageEnglish

Related product manuals