47
HDE 04.10.2021 732.22.024
The system can be extended to include the following components, see also 9. Extensions
and connections, page 70.
Extension Description
MLA 6P multi-lock adapter Electronic output extender for connecting up to
6 EFL 3 / EFL 3C furniture locks in keyed alike operation.
Multiple MLA 6P devices can be connected one after the
other (cascaded) for each EFL 3 / EFL 3C connection to
furniture terminal FT 200 / FT 200 CAP.
When doing this, each MLA 6P requires its own voltage
supply, for which additional PS4 power supply units are
required.
Attention: please note the rated values of the system
components!
Multi-lock adapter MLA 8 Electronic output extender for connecting up to
8 EFL 3 / EFL 3C furniture locks in keyed alike and /
or keyed to differ operation.
Up to 16 MLA 8 devices (= 128 furniture locks) can be
connected one after the other in series (cascaded) to the
FT 200 / FT 200 CAP for exclusive keyed alike operation.
Attention! Please note the rated values of the system
components!
Feedback from the furniture locks is not possible with a
series connection.
With keyed to differ operation, only one MLA 8 can be
connected to the FT 200 / FT 200 CAP. The total number
of EFL 3 / EFL 3C furniture locks can therefore be
extended to a maximum of 12.
The EFL 3 / EFL 3C feedback contacts for monitoring can
be interrogated by the terminal using macro programs.
Note: the order of the EFL 3 / EFL 3C connections always
starts at the FT 200 / FT 200 CAP, so that if there are more
than four EFL 3 / EFL 3C, the 5
th
will be connected to
output 1 of the MLA 8.
Signal generator, visual (LED) Visual display of the locking status
• LED red/green
Illuminates in the same way as the LED of the FAN 200
antenna
Signal generator, acoustic • Acoustic signalling of the locking status
Piezo sound generator (105 dB)
• Macro required (
Macros, page 48)
Green connector
9. Extensions and
connections, page 70
.
Potential-free input/output
Relay output port NO, NC, COM
Digital input port
• Macro required (
Macros, page 48)
ins-src-732.22.024.book Seite 47 Mittwoch, 13. Oktober 2021 1:58 13