EasyManua.ls Logo

Häfele FT 200 - Technical Data

Häfele FT 200
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
HDE 04.10.2021 732.22.024
3.2 Technical data
FT 200 / FT 200 CAP furniture terminal
Antenna FAN 200
Feature Value
Power supply 12 V DC, ± 20 %
Current consumption max.
(incl. 4x EFL 3)
690 mA
Ambient temperature 0 - 55 °C
Relative humidity 10 to 95%, not condensed
Degree of protection IP20
Relay output port NO, NC, COM 125 V AC / 60 V DC, 1 A max.
Transponder technology Tag-It, Mifare Classic EV1, Mifare DESFire EV1 and EV2.
The transponders used for Dialock software applications must
be qualified and encoded by Häfele.
Approvals CE, FCC / IC, Japan Radio Law
Connections
Connection cable (150 mm) with
plug
Micro AMP WR MPC3-3.00 mm
Socket, antenna SMB coaxial
Socket, MLA 8 RJ 11
Socket, EFL 3 / EFL 3C RJ 10
Socket, optical signal generator
(LED)
SM02B-SFHRS-TF
Socket, acoustic signal generator SM02B-SFHRS-TF
Socket, AUX Term block plug WR-TBL
Socket, OUT (supply voltage) Micro Power Connector WR-MPC3
Socket, IN (supply voltage) Micro Power Connector WR-MPC3
Feature Value
Degree of protection IP 67
Transponder technology Tag-It, Mifare Classic EV1, Mifare DESFire EV1 and EV2.
The transponders used for Dialock software applications must
be qualified and encoded by Häfele.
Read range 25 mm
Environment Not suitable for installation:
• in metal
in metal-coated furniture
• behind mirrored surfaces
Minimum distance between two
antennas
250 mm
ins-src-732.22.024.book Seite 49 Mittwoch, 13. Oktober 2021 1:58 13