ā 12 ā
Target / Max Temperature Limits
Cycle PW4 MW Rinse FR
Light 125 140
Normal 125 140
Auto 130 130 145
Heavy 130 130 130 145
1-Hour 135 140
Heater Algorithm, Dry Cycle
Normal with Heated Dry
Time
(minutes)
Calrod Description
7 Calrod on
27 Calrod Pulse - 2 minute on/1 minute off
14 Calrod off - Cool Down
Normal with Temp Boost or Steam/Sani Selected
7 Calrod on
57 Calrod Pulse - 1 minute on/1 minute off
Normal with Boost Dry
7 Calrod on
57 Calrod Pulse - 2 minute on/1 minute off
15 Calrod off - Cool Down