When the engine is running and the gearbox
oil temperature exceeds the normal range (60
℃-120℃), the alarm light will turn on.
Caution
If the alarm light turns on, please stop
operation immediately and reduce
engine speed to cool down until the light
turns off. The oil level should be checked
or other inspections should be
conducted.
Seat safety belt alarm indicator light (optional
configuration)
When the start key is in the “┃”, position, the
engine is not started and the driver is not on
the driver's seat. If the safety belt is not
fastened properly, the safety belt alarm
indicator light will turn on.
If the safety belt is not fastened or loose when
the driver is operating the vehicle, the buzzer
alarm will sound and the safety belt alarm
indicator light will turn on at the same time.
This is to remind the driver to safely park and
refasten the safety belt; the buzzer alarm will
then stop and the safety belt alarm indicator
light will turn off.
Air filter alarm indicator light
When the light turns on, it indicates that the
filter of the air intake system is blocked and the
forklift must be stopped to clean the filter.
Engine fault indicator light [for forklift trucks
with an electronically controlled engine]
When the light turns on, it indicates that there
is a fault and the forklift must be stopped
immediately.
Maintenance personnel can press the right key
of the instrument to check or connect the ECU
diagnosis interface with the diagnostic
equipment to read the fault code information
stored in the ECU.
Low brake pressure alarm indicator light
The indicator light in the forklift truck is not
operative.
OPS indicator light
When the light turns on, it indicates that the
driver is not on the driver's seat or is not sitting
properly.
Regen indicator light
There are three kinds of working status: Driving
regen, parking regen, and service regen
(aftersales solution).
In the first case, the regen indicator light turns
on normally and is in the regen working status.
At that time, manual intervention is not
required and normal working status can be
maintained. The light will automatically turn off
after the regen prompt, which also indicates
that the treatment of particulate matter is
completed.
The driver should reduce the light-load running
time as much as possible to increase the
exhaust temperature and shorten the regen
time.