In the second case, it prompts that the parking
regen should be started.
Parking regen conditions:
1
The forklift truck should be parked on
a well-ventilated flat road.
2 Engage the hand brake.
3 Release the accelerator pedal.
4
Keep the direction lever in the
neutral position (gear N).
5 Warm up the forklift truck until the
water temperature reaches 70℃.
Install a hazard warning sign near the exhaust
vent.
Start parking regen (see operating instructions
for the instrument keys)
Warning
Because the regeneration temperature is
high, there should not be any
combustible materials near the exhaust
system or the truck. Do not regenerate
in gas stations, dusty places or other
flammable and explosive areas.
At the end of parking regen, the light will
automatically turn off; the engine can be shut
down after waiting for 2-3 min until the engine
reverts to normal idling.
Caution
Parking regen: The parking conditions
must be suitable for heat dissipation.
Stay away from inflammables and keep a
safe distance from people.
The driver should pay attention to safety,
should not leave the site, and should
monitor the engine conditions during
regen.
The driver should not stop the engine
during regen except in emergencies,
otherwise it is likely to cause a DPF fault.
Warning
If it is necessary to inhibit parking regen
in an emergency, only one of the
conditions②③④to exit parking regen
needs to be met.
After it is confirmed that the
surrounding environment around the
forklift truck is safe, regen can be
restarted, which generally should not
exceed 40 min.
W98/W97
The regen indicator light turns on when driving
and the forklift truck can continue to be used
normally or can be driven to a safe position for
parking regen.
If the regen indicator light turns on when
driving and the engine fault indicator light
turns on as well, maintenance personnel or
aftersales staff for the plant area should be
contacted to check the engine fault code. Start
parking regen after confirming that there are
no other faults.
Caution
If the two indicator lights turn on and
there is no parking regen within 2h, the
DPF is likely to be blocked, parking regen
will not start, and the DPF may be
damaged, causing maintenance expenses.
Fault code
SPN:3701 FMI:15
Third case, service regen.
When the DPF has been severely blocked, the
engine has reduced power and torque, and the
forklift truck does not work normally, aftersales
staff should be contacted for service regen.
Fault code
SPN:3701 FMI:16
Exhaust system fault indicator light
If the EATS has a fault or exceeds the
designated operating parameters, the engine