Procedure
1. For gear units with horizontal LSS with integrated lifting eyes: make sure that the
maximum angle (X) of the lifting cables (A) is 45° in the plane of the long side of the
gear unit.
2. For all other gear units, make sure that all lifting cables (B) are vertical and parallel to
each other.
3. Connect the lifting equipment to the gear unit. Use all lifting points of the gear unit.
4. Lift the gear unit. Use the safe lifting equipment.